Hard x-ray pluse height analysis


[Objectives]
Radial profile and energy distribution of fast electrons produced by lower hybrid waves are measured.

[Detectors, Diagnostic Method]
Seven channel sodium-iodide (NaI(Tl)) scintillator-photomultiplier combination is employed to measure the x-ray spectra from 80 keV to 1000 keV.

Detectors are shielded by 23 cm of lead and 50 cm polyethylene to reduce the back-ground gamma-rays.

[Specifications]
-Time resolusion: 50/200 ms (spectra), 1/4 ms (count) [for 12.8/51.2 s]
-Energy range: 80 - 1000 keV
-Position : P-1 section, IN-2A-c port (poloidal array :7 channel)
: P-7 section, R-9-c port (counter-tangential :1 channel)
: P-8 section, R-6-e port (co -tangential :1 channel)
-Detector: NaI(Tl) 5.08 cm in diameter, 5.08 cm in length